• HOME
  • ABOUT US
    • About TALOS
    • Management Team
    • Manufacturer
  • SOLUTIONS
    • Design Solutions
    • Project Solutions
  • PRODUCTS
    • P3000
    • P5000
    • PK10
    • PK500
    • Folding VAWT
    • Super Turbine
  • PROJECTS
    • Finished Projects
  • INNOVATIONS
    • New Projects & Testing
  • CUSTOMER FEEDBACK
  • CONTACT
    • Contact Us
    • OUR KEY DISTRIBUTORS
  • More
    • HOME
    • ABOUT US
      • About TALOS
      • Management Team
      • Manufacturer
    • SOLUTIONS
      • Design Solutions
      • Project Solutions
    • PRODUCTS
      • P3000
      • P5000
      • PK10
      • PK500
      • Folding VAWT
      • Super Turbine
    • PROJECTS
      • Finished Projects
    • INNOVATIONS
      • New Projects & Testing
    • CUSTOMER FEEDBACK
    • CONTACT
      • Contact Us
      • OUR KEY DISTRIBUTORS
  • HOME
  • ABOUT US
    • About TALOS
    • Management Team
    • Manufacturer
  • SOLUTIONS
    • Design Solutions
    • Project Solutions
  • PRODUCTS
    • P3000
    • P5000
    • PK10
    • PK500
    • Folding VAWT
    • Super Turbine
  • PROJECTS
    • Finished Projects
  • INNOVATIONS
    • New Projects & Testing
  • CUSTOMER FEEDBACK
  • CONTACT
    • Contact Us
    • OUR KEY DISTRIBUTORS

Super Turbine

The core technology of the Super Turbine is called “active real-time attack angle regulation” and is based on the “Bernoulli” principle. On a fixed circular orbit, based on blade position, wind direction, and speed, the adjustment of the relative angle of all blades is automatically done in real time. This makes wind energy conversion the most efficient way. Super Turbine capacity currently ranges between 7 to 50 MW. This technology is patented worldwide and authorized by TALOS.

Wind Tunnel Test 2

4m/s wind speed tunnel test

Wind Tunnel Test 1


2m/s wind speed tunnel test

 

The test device is a 1m x 1.36m VAWT in a wind tunnel with 2m/s wind speed. The torque is (0.9-1)N.M at 44 RPM. The conversion rate of wind energy to mechanical energy reaches 68%, surpassing the limit of 59.3% by Betz Law based on HAWT windmills: a single disk rotation in a two-dimensional space. Whereas the VAWT is a multiple disk rotation in a three-dimensional space. Hence the TALOS wind energy conversion rate is higher than any HAWT product according to Betz Law.

Tower Structure Calculation

Example 1

Tower Structure Calculation

Example 2

P10K-AB, High Speed Wind Test 1

Inner-Mongolia Test Farm, China

P5000-AB, High Speed Wind Test 2

Inner-Mogolia Test Farm, Chinan

P5K-AB Test Report

Tested at Inner-Mongolia Test Farm, China 2015

P5K-AB VAWT Test Report Inner-Mongolia (pdf)

Download

P10K-AB, High Speed Wind Test 3

Inner Mongolia Test Farm, China

P10K-AB, Low Speed Wind Test 1

Inner Mongolia Test Farm, China

P10K-AB, Low Speed Wind Test 2

Inner Mongolia Test Farm, China

P10K-AB VAWT

University of Riyadh, Saudi Arabia

University of Riyadh Test Data in 2015

VAWT-TaQati pilot plant data-C (pdf)